Displacement Pump Replacement for 695/795
311365H 39
Installation
1. Extend pump piston rod 1.5 in. Apply grease to
top of pump rod at (A) or inside connecting rod.
2. Install pump pin (44). Verify retaining spring
(43) is in groove of connecting rod (85).
3. Push pump up until pump threads engage.
4. Screw in pump until threads are flush with drive
housing opening. Align pump outlet to back.
5. Install washers, o-rings and suction tube (76)
and hose (94).
6. Screw jam nut (56) up onto pump until nut
stops. Tighten jam nut by hand, then tap 1/8 to
1/4 turn with a 20 oz (maximum) hammer to
approximately 75± 5 ft-lb (102 N•m).
7. Install pump rod shield (108) with screw (31).
8. Fill packing nut with Graco TSL until fluid flows
onto top of seal.
If pump pin works loose, parts could break off
due to force of pumping action. Parts could
project through the air and result in serious
injury or property damage.
NOTICE
If the pump jam nut loosens during operation,
the threads of the drive housing will be
damaged.
ti7171a
A
1.5 in.
ti7169a

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ultra max ii and is the answer not in the manual?

Graco ultra max ii Specifications

General IconGeneral
Max Pressure3300 PSI
MotorOilless, axial cam
SeriesUltra Max II
Power SourceElectric
Voltage120V
Hose Length50 ft
TypeAirless
Max Tip Size0.017 inches
Spray Tip Size0.009 - 0.017 inches

Related product manuals