5. Once you enter the weight value, double-press on the ¿ key to validate
and move to next step. The display will show the blinking message
-CAL-“ while acquiring the calibration value.
6. Lastly, it will show the message GEOfor a few seconds, asking for the
code of the geographical location where you did the calibration. The
geographical location code is a value from 0 to 31, which you have to
choose from the attached table. Use the ß and à keys to change the
value and validate by pressing on the ¿ key.
7. Lastly, the message SAVE will briefly appear, indicating that the
calibration has been saved in the non-volatile memory. The indicator
returns to normal use mode, displaying the weight on the load receptor.
If the automatic correction of weight reading according to geographical
latitude and height (option G-COR”) is activated, the next time the scale is
switched on after a calibration, once the display test and the initial welcome
message are completed, the user will be asked to input the value
corresponding to the geographical zone where the scale will be used.
Once the value has been entered for the geographical zone in which the scale
is used, it is recorded in the non-volatile memory and will not be requested
again.
The geographical area where the scale is used can be modified later whenever
you wish by entering the menu with NEnU à SCALE à CAL à G-SET à
GEO à G nn (for nn {0-31}).
The automatic correction of the setting according to geographical area can be
disabled by entering the menu with NEnU à SCALE à CAL à G-SET à G-
Cor à OFF.
16.3 Table of geographical adjustment values
Geographical latitude in
the northern or southern
hemisphere in degrees
and minutes.
Elevation above sea level in metres
0
325
650
975
1300
1625
1950
2275
2600
2925
3250
325
650
975
1300
1625
1950
2275
2600
2925
3250
3575
Elevation above sea level in feet
0
1060
2130
3200
4260
5330
6400
7460
8530
9600
10660
1060
2130
3200
4260
5330
6400
7460
8530
9600
10660
11730
00°00' - 05°46'
5
4
4
3
3
2
2
1
1
0
0
05°46' - 09°52'
5
5
4
4
3
3
2
2
1
1
0