20 Error messages
AdC-E
ADC fail: No ADC response
Indicat
or
fault
.
See technical
service.
AdC-h
Load cell input s
ignal too high
(> 20mV)
Damaged load cell.
Wiring default.
AdC-l
Load cell input s
ignal too
low
(< -20mV)
Damaged load cell.
Wiring default.
BAt
Low battery.
Connect the AC / DC adapter
to charge the battery.
Err 0
a)
Auto
-
zero device out of
limits
b) A stable measure could not
be obtained by attempting
to initial zero
Empty the
load
rece
ptor
before power on the scale.
Err N
Adjustment weight
> Max
Adjustment weight must be
<
Max
Err d
The division must be
> 10 ADC
counts
The resolution is too high,
change the division to a
higher value.
Err C
Cannot
obtain
a
stable
measurement for scale
adjustment
-O L-
Overload:
weight
> Max + 9 · div
LOCK
K
eypad lock is enabled.
nOrtC
The optional RTC board is
missing or damaged.
tICOn
A totalization ticket has already
been started.
Print the total before
starting
a new ticket.