P a g e | 55
HT70X User manual
Version 1.0.9.4
Disable Network
Echo Suppressor
Default is No.
If set to “YesNEC will be disabled per call base. Recommended for FAX/Data
calls.
Outgoing Call
Duration Limit
Configure the time limitation of outgoing calls. 0-180 minutes, default is 0 (No
Limit).
Ring Frequency
Configure ringing frequency for your phone. 15-60 Hz, default is 20 Hz.
Enable High Ring
Power
Default is No.
If it has difficulties to ring the FAX machine or phone. Enable to push higher ring
power through FXS port.
Ring Tones
This function lets you configure ring tone cadence preferences. User has 10
choices.
The configuration, completed in Distinctive Ring Tones block in the same page,
applies to ring tones cadences configured here.
SIP Use ID
User account information, provided by VoIP service provider (ITSP). Usually in
the form of digit similar to phone number or actually a phone number.
Authenticate ID
SIP service subscriber’s Authenticate ID used for authentication. Can be
identical to or different from SIP User ID.
Password
SIP service subscriber’s account password for HT704 to register to (SIP)
servers of ITSP.
Name
Any name to identify this specific user.
Profile ID
Select the corresponding Profile ID between Profile 1 and Profile 2.
Hunting Group
This feature enables the HT704 to register all existing FXS ports with the
same phone number.
Each incoming call will be routed to first available port in Linear or Circular
mode.
User may configure all ports as members of the same Hunting Group or it may
configure different port combinations for more than one Hunting Group. For
example:
Ports 1, 3 and 5 are members of the same Hunting Group, the rest of the ports
may have separate numbers and may be reached independently.
Any port, member of a Hunting Group that is not registered with a SIP
account, will be able to place outbound calls using the SIP credentials of the
primary Hunting Group port.

Table of Contents

Other manuals for Grandstream Networks HT701

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks HT701 and is the answer not in the manual?

Grandstream Networks HT701 Specifications

General IconGeneral
BrandGrandstream Networks
ModelHT701
CategoryAdapter
LanguageEnglish

Related product manuals