EasyManuals Logo

Grant Vortex Eco User Manual

Grant Vortex Eco
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
Oil Storage &
Supply System
Main Burner Components
Remove the control panel (secured by
two screws) to gain access to the
burner. It may be necessary to remove
the burner from the boiler to access
connections in the fuel pump.
To do this, unscrew the single nut at
the top of the burner (using a 13mm
spanner) and rotate the burner
clockwise and withdraw the burner from
the boiler, as shown in Figure 3-6.
Burner Connection
The procedure is as follows:
1. Remove and discard the blanking
plugs from the suction (inlet) and
return connections of the pump.
Refer to figure 3-7.
2. Connect the suction and return oil
flexible fuel lines to the pump.
3. Connect the
3
/8" to
1
/4" BSP
adaptor to the flexible fuel line using
the adaptor supplied. The supply
enters through one of the holes in
the casing.
Item Description
01 Inlet (suction) port
02 Return port
03 Bleed and pressure gauge port
04 Vacuum gauge port
05 Pressure adjustment
06 Nozzle outlet
01
Figure 3-6: Burner removal
Figure 3-7: Danfoss BFP11 R3 oil pump
05
B
urner fixing nut
06
04
02
03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grant Vortex Eco and is the answer not in the manual?

Grant Vortex Eco Specifications

General IconGeneral
ModelVortex Eco
CategoryBoiler
Fuel TypeOil
TypeCondensing
Warranty2 years

Related product manuals