FC8000-UM-251-9370 8-11
8. TROUBLESHOOTING
8.4.4 Error Messages on ARMS
Error
code
Error Display Cause Solution
E04001
E04001 ARMS
AXIS SET ERROR!
SET AGAIN
TilttoadjustwithAXIS
ALIGNMENTistoolarge.
Reloadthemedia.
E04002
E04002 ARMS
ADJUSTMENT ERROR
DISTANCE
SET AGAIN
Itisoverthesettingrangeofthe
distanceadjust.
Settosmallervalue.
E04003
E04003 ARMS
IT IS NOT POSSIBLE
TO ADJUST IT.
Failedtoadjustthesensorlevel. Thismediacannotbeused.
Useothermediapossibleto
detecttheregistrationmark.
E04004
E04004 ARMS
DISTANCE
ADJUSTMENT ERROR
SET AGAIN
Itisoverthesettingrangeofthe
distanceadjust.
Settosmallervalue.
E04005
E04005 ARMS
MARK SCAN ERROR!
Couldnotscantheregistration
marks.
Checktheregistrationmark
scanningposition.
E04006
E04006 ARMS
BUFFER OVERFLOW
Amountofdatahasexceededthe
I/Obuffersizeforthesegment
arearegistrationmark.
Decreasethedata.
E04007
E04007 ARMS
ILLEGAL PLOT AREA
Testpatternplottingpositionisnot
withintheplottingareaforsensor
positionadjustment.
Movethemediatowardcenter
andplotthetestpattern.
E04008
E04008 ARMS
MARK SCAN ERROR!
MEDIA END DURING
MEDIA DETECTION
Mediaendwasdetectedwhile
detectingtheregistrationmark.
Checkthemedia.
Checktheprintpositionofthe
registrationmark.
E04009
E04009 ARMS
MARK SCAN ERROR!
NOT ENOUGH LENGTH
IN +X DIRECTION
Ithasexceededdetectionarea
whiledetectingtheregistration
mark.
Checkthemedia.
Checktheprintpositionofthe
registrationmark.
E04010
E04010 ARMS
MARK SCAN ERROR!
EXCEED CUTTING
AREA DURING
+X DETECTION
Ithasexceededdetectionarea
whiledetectingtheregistration
mark.
Checkthemedia.
Checktheprintpositionofthe
registrationmark.
E04011
E04011 ARMS
MARK SCAN ERROR!
NOT ENOUGH LENGTH
IN -X DIRECTION
Ithasexceededdetectionarea
whiledetectingtheregistration
mark.
Checkthemedia.
Checktheprintpositionofthe
registrationmark.
E04012
E04012 ARMS
MARK SCAN ERROR!
EXCEED CUTTING
AREA DURING
-X DETECTION
Ithasexceededdetectionarea
whiledetectingtheregistration
mark.
Checkthemedia.
Checktheprintpositionofthe
registrationmark.