3−41
CHAPTER 3 Settings and Measurement
(7)-1 File Operation
Operate files in the main memory and USB device. For details on file operation, see on page 3-44.
(7)-2 Data Save
Saves data being replayed to the internal memory or USB memory.
<If the naming method is Auto> <If the naming method is Arbitrary>
Setting Description
(1) Folder Specify a folder to which you want to save data. Refer to page 3-44,
"File box" for details.
(2) File Specify a file to which you want to save data. Refer to page 3-44, "File
box" for details.
(3) File Type Sets the file format used to save data.
GBD: Creating a data file in Graphtec's proprietary binary format
* Data tampering can be prevented.
CSV: Creating a data file in text format
* Replaying on the GL820 is not available.
(4) Name Type Set how a data file should be named.
Auto : Automatically supplies the file name.
Example: 20050101-123456_UG.GBD
Number part : File creation date
* The file is created on January 1,
2005, 12:34:56 in this example.
UG : User number of the user capturing data
UG: Guest
U1: User 1
U2: User 2
GBD : Data format GBD
(Binary data)
CSV (Text format)
Arbitrary : Data is captured to a file with an entered file name.
Sequentialnumber
:
A file is created with an arbitrary file name that has
beenentered,followedbyasequentialnumber.
(5) Save Range Sets the range of data to be saved.
All Data : Saves all data regardless of the cursors.
Data between Cursors : Saves only a range of data between cursors
A and B.
(7)-3 Remove/Exchange USB Memory
The GL820 allows you to exchange the USB memory while data is captured to it.
Exchange the USB memory in accordance with the following procedure: