XCU eXchangeable Control Unit User’s Guide (v1.6) 19
Chapter 2 - Installation
2.1.4 Connecting studio cabling
The studio cabling (main video outputs, control and intercom connections, studio signalling)
can now be connected according to your application and studio configuration. Refer to “Cradle
back panel” on page 50 for connectors and signals available on the cradle.
More information about studio signalling, control network, intercom cabling and other studio
infrastructure can be found further down this chapter.
2.2 Mounting the XCU
To mount the XCU into the cradle, proceed as follows:
• Place the XCU onto the sliding rails of the cradle, slide the unit into the cradle and push
firmly.
• Push down the right and left locking handles until they snap down.
To remove the XCU from the cradle, proceed as follows:
• Hold down the springs inside the locking handles and at the same time swing them open.
• Pull out the XCU from the cradle by pulling the XCU at its sides.
• Now the transmission and mains cables can be connected. Refer to “XCU back panel” on
page 49 for connectors and signals available on the XCU.