20 XCU eXchangeable Control Unit User’s Guide (v1.6)
Chapter 2 - Installation
2.3 Setting up the control network
The XCU is connected to the control network hub or router via an Ethernet cable (straight-
through, not cross-over) via the C2IP (RJ45) connector. An OCP 400 (Operational Control Panel)
and, if required an MCP 450 (Master Control PC), are also connected to the Ethernet network
via a hub or router. An OCP 400 can also be connected directly to the XCU using a (cross-over
or a straight-through) Ethernet cable.
The IP address and other options for the Ethernet connection can be set up in the XCU menu.
By default, the Ethernet connection is set up for Auto IP configuration.
2.4 Setting up intercom
Connect the studio intercom system to the rear of the XCU. Both a two and four-wire cabling
can be used. In the
AUDIO/INTERCOM > INTERCOM > ENG > WIRE MODE menu select the
cabling system: 2wire or 4wire.
The wiring of the panel connector is shown below for two-wire and four-wire systems.
2.4.1 Two-wire systems
2.4.2 Four-wire systems
Signal Value
Signal level 0 dBu (RMS)
Load impedance 200
Voltage level max. 40 VDC
Housing
Prod
Housing
Eng in/out
Prod in/out
Signal Value
Output signal level +6 or 0 dBu (RMS) selectable
Output impedance max. 50 symmetrical
Input signal level +6 or 0 dBu (RMS) selectable
Impedance min. 9 k symmetrical
Housing
Eng in/out
Prod in/out
Housing
Prog in ret
Prog in
Prod in ret
Prod in
Eng in ret
Eng in