34 XCU eXchangeable Control Unit User’s Guide (v1.6)
Chapter 4 - Operation
Camera Power indicator
A green light means that the connected camera is powered by the XCU and switched on. A
blinking green light indicates that a camera is connected but not switched on. A red light
indicates a power supply error (e.g. a power overload).
Cable indicator
This green indicator lights when a transmission cable is correctly connected between the
camera and XCU. A blinking red light indicates a missing or interrupted transmission cable. A
red light indicates that a cable is connected but there is an error (e.g. a short circuit).
On Air indicator
The On Air indicator lights (red) when the connected camera is switched On Air.
On Air Yellow indicator (or ISO)
The On Air Yellow indicator lights when the connected camera is switched to On Air Yellow or
when the camera is in ISO mode.
On Air Green indicator (or Call)
The On Air Green indicator lights when the connected camera is switched to On Air Green or
when a Call signal is sent or received.
Power indicator
This green indicator lights when the XCU is switched on. A blinking green indicator means that
the unit is shutting down.
4.2 Transmission diagnostics on the OCP 400
With an Operational Control Panel (OCP 400) is connected to the system, transmission can be
monitored in the diagnostics page of the panel:
Indication Description
Cable or signal quality is OK.
Cable or signal quality is below optimum, transmission is still in operation. The
quality level can vary between 6 (high) and 0 (low) units.
TOGGLE
PREV NEXT
EXIT
Signal NoSignal
FibB Cable ERROR
Signal
FibA Cable
|
OK
Signal quality from XCU to
camera
Sgnal quality from camera to
XCU.
Cable quality from camera to
XCU.
Cable quality from XCU to
camera