Connections - Installation
15
M_XCOM_EN_B
2. Connections
The di󰓐erent elements of the equipment must be connected with the power o󰓐. The
power supply should be connected last.
TousetheCCU,3connectionsmustbeperformed,inthefollowingorder(minimum):
Wiringofthe"Stopmarking"contact:SubD9connector(female)-withjumpers
Markinghead
Power supply
Wiringofthe"Stopmarking"contact
The machine comes delivered with a SubD 9 point connector with bridge so that it can be used immediately.
It must be connected to the dedicated Inputs/Outputs connector located on the right side of the CCU.
The connector supplied is only used to test the machine. Under normal operating conditions, open the electrical
connectionbetweenpins5and9toactivatethe"Stopmarking"function.Ifthisconnectionisnotperformed,
theStopfunctionisactiveandnomarkingispossible.
ConnectionofthemarkingheadtotheCCU
ConnectthemarkingheadandtheCCUviatheirconnectioncable.Firmlyinserttheplugs,andtightenthe
lockingrings.Checkthattheconnectionisappropriate.
Power supply connection
Plug the CCU to the power supply using the cable provided.
Placetheswitchinthe"I"position(On).
The machine is operational.