Skywarn
EXPERT BELOW
Delay
Delay Time
AudioBoost
Hit Count
On or Off
When On, the TGRP object is a member of the
Favorites Scan List.
On or Off
When On, the CONV object is a member of the
Skywarn Scan List.
On or Off
Controls whether a Delay is used to wait for reply
traffic after a transmission on the TGRP.
1-200 x 100 mS
Sets the amount of time (in 100 millisecond
intervals) for the wait for reply delay if Delay is On,
e.g., 20=2 seconds.
On or Off
Applies a 6 dB boost to audio levels when the
object is active
Numeric value
Increments each time a transmission is received on
the SWPR object. Global “Hit Counts” must be set
to ON. Press the
Dflt softkey to reset to 0.