Design and Selection
34
return.
When load of the FCU is too large, the unit would always run under high frequency, which is
unhelpful for energy conservation.
Type
Air Volume
(m
3
/h)
Cooling
Capacity
(kW)
Heating
Capacity
(kW)
Static
Pressure
(Pa)
Appearance
Wall
mounted
type
166~1020
2.1~5.4
3.15~8.5
——
Concealed
ceiling type
213~2380
1.85~12.8
3.1~21
12, 30
Floor ceiling
type
213~2040
1.9~10.8
2.8~16.2
——
Cassette
type
480~1700
4.5~9
6.8~13.7
——
6 Selection of the Water Tank
6.1 Specifications of the Water Tank
SXVD200LCJ/A-K
220~240V-1N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-K
SXVD200LCJ2/A-K
220~240V-1N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
SXVD300LCJ2/A-K
SXVD200LCJ/A-M
380~415V-3N-50Hz
A single coil with the electric heater is integrated, used for floor heating system
SXVD300LCJ/A-M
SXVD200LCJ2/A-M
380~415V-3N-50Hz
Dual coils with the electric heater are integrated, used for floor heating system and the solar system
6.2 Volume Selection of the Water Tank
6.2.1 Selection Based on Water Consumption Per Capita
Building Type
Unit
Daily Water Consumption (L)
Water Temperature (°C)
House
Per person, Per day
40~80
60