555C Electric Bender Classic
Grounding Instructions
This tool must be grounded. In the event of a malfunc-
tion or breakdown, an electrical ground provides a path
of least resistance for the electric current. This path of
least resistance is intended to reduce the risk of electric
shock.
This tool’s electric cord has a grounding conductor and
a grounding plug as shown. Do not modify the plug.
Connect the plug to a corresponding GFCI-protected
receptacle that is properly installed and grounded in
accordance with all national and local codes and ordi-
nances.
Do not use an adapter.
Electric shock hazard:
• Do not modify the plug provided
with the tool.
• Connect this tool to a grounded
receptacle on a 20 amp ground
fault protected circuit.
Failure to observe these warnings
could result in severe injury or death.
ReceptaclePlug
NEMA L5-20 Twist-Lock
20 Amp/120 Volt
Plug and Receptacle