Stitch forming mechanism
5. Adjustment of the needle clearance in relation to the needle slot
Requirement:
Between the rear edge of the needle and the rear edge of the needle slot in the needle plate, there should
be a clearance of 0.2 mm (fig. 5a).
Note:
For needle system 130/705 H, the needle size increases the actual size of the needle only at the front of
the needle. For example, a size 100 needle will be positioned with its needle point exactly in the center of
the needle slot (viewed from front to back) while the needle point of a size 80 needle will be positioned
with its needle point slightly towards the rear.
Check:
Insert a new size 100 system 130/705 H needle.
Set control knob to straight stitch and “left” needle position (fig. 5).
Remove the presser foot shoe.
Turn the handwheel until the needle is at its lowest position.
The needle must now be evenly centered from front to back in the needle plate slot.
Adjustment:
Loosen screw 15 with a 2.5 mm Allen key (fig. 5).
Move the complete bolt 16 together with the needle bar frame 17 forward or backward until the needle
is centered exactly in the needle plate slot (fig. 5b).
Tighten screw 15.
Test:
Carry out a visual test for the straight and zigzag stitches.