46
29. Changing the stitch length control
Removal:
Disconnect the plug from the electrical outlet.
Fold up the carrying handle.
Turn out both arm cover retaining screws and remove arm cover.
Turn out both stand cover retaining screws and remove stand cover.
Loosen both face cover retaining screws and remove face cover.
Remove the detachable work support (accessory box) by pulling it to the left.
Take out screw 88 with washer 89 (fig. 29).
Remove cover plate 90.
Turn out both lock washers 91 (fig. 29a).
Turn out Phillips screw 92 (fig. 29b).
Remove stitch length control plate 93 with spring 94.
Disconnect spring 95 (fig. 29a).
Turn out both Phillips screws 96 (fig. 29b).
Detach the connecting rods of the stitch length control from the guide pins of the slide way.
Remove the stitch length control 97.
Refitting:
Refit the stitch length control 97 in such a way that both connecting rods engage in the guide
pins of the slide way.
Reinsert both Phillips screws 96 and loosely attach the stitch length control.
Refit both lock washers 91 (fig. 29a).
Connect spring 95.
Refit stitch length control plate 93 with spring 94 (fig. 29b)
Tighten Phillips screws 92 and both Phillips screws 96.
Refit cover plate 90 (fig. 29) and tighten it with washer 89 and screw 88.
Carry out a function check.
Carry out an electrical safety test in accordance with VDE 0701 using testing appliance
ABB Metrawatt 5013.