6
2. Adjustment of the needle zero point for the straight stitch
Requirement:
When the control knob for utility and zigzag stitches is set to “left” needle position, the machine
must sew a perfectly straight stitch.
The lifting clearance between the feeler finger 2 and the highest points of the zigzag cam 1 must
be 0.1-0.2 mm (fig. 2 and 2b).
Check:
Fold up the carrying handle.
Turn out both arm cover screws and remove arm cover.
Set stitch control knob as shown in fig. 2.
Run the machine slowly.
The needle bar frame should have no sideways movement.
The feeler finger 2 must not touch the highest points of the zigzag cam 1 (fig. 2b).
Adjustment:
Turn the handwheel until the feeler finger 2 is at the highest point of the zigzag cam 1.
Loosen nut 5 (fig. 2a and 2c).
Turn screw 6 until it touches zigzag width cam 7 and the clearance between feeler finger 2 and
the highest point of zigzag cam 1 is 0.1-0.2 mm (fig. 2b).
Tighten nut 5 without turning screw 6 (fig. 2c).
Test:
Run the machine slowly.
The needle bar frame is not allowed to make any sideways movement.
The lifting clearance between the feeler finger 2 and the highest point of the zigzag cam 1 must
be 0.1-0.2 mm (fig. 2b)