6.7 Inverter demand response modes (DRMS)
This series inverter has the function of demand response modes, We use 1 6-Pin
socket as inverter DRMS connection.
6.7.1 16-Pin socket pin assignment
Assignment for inverters capable of both charging and discharging
6.7.2 Method of asserting demand response modes
Socket asserted by
shorting pins
Operate the disconnection device.
Do not generate at more than 50% of rated power.
Do not generate at more than 75% of rated power
and reduce the reactive power as far as possible.
Increase power generation (subject to constraints
from other active DRMs).
DRMS application description
> Applicable to AS/NZS4777.2:201 5 or Commission Regula-
tion (EU) 201 6/631.
> DRMO, DRM5, DRM6, DRM7, DRM8 are available.
Damage to the inverter due to moisture and dust penetration
> Make sure the cable gland has been tightened firmly.
> If the cable gland are not mounted properly, the inverte r can
be destroyed due to moisture and dust penetration. All the
warranty claim will be invalid.
Excessive voltage can damage the inverter!
External voltage of DRM PORT don't over
+5V.