8 Working Mode
8.1 Normal mode
In this mode, the inverter works normally.
^ When the DC voltage is greater than 250V, the energy is sufficient, and the grid
voltage frequency meets the grid-connected requirements, the inverter will
convert the energy of the solar panels into AC power and export to the grid,
and the green LED will light up.
^ When the DC voltage is lower than 1 80V, the inverter will automatica lly discon-
nect from the grid and exit the normal operation mode. When the input volt-
age reaches the requirement again and the grid voltage and frequency return
to normal, the inverter will automatically connect to the grid.
8.2 Failure mode
The inverter controls the chip monitors and adjusts the state of the system in real
time. When the inverter monitors any unexpected conditions,such as system failure
and inverter failure,the display will show the fault information.In the failure
mode,the inverter will indicate The leaves of the window will turn red and the
inverter output will be disconnected from the grid.
8.3 Shutdown mode
When the sunlight is weak or there is no sunlight,the inverter will automatically
stop running.When in shutdown mode,the inverter basically does not consume en-
ergy from the grid or solar panels,and at the same time,the inverter's display
screen and LED lights will be turned off.