Tips and disclaimers
When the inverter leaves the factory, the grid -connected voltage and frequency
are set in accordance with the latest domestic standard;
If the grid voItage is close to or higher than the domestic legal requirements, the
inverter cannot be connected to the grid. After obtaining the permission of the
local power operator, the user can choose other voltage levels according to the
voltage situation of the grid connection point.
Excessive grid voltage may affect the normal use and service life of
home appliances on the grid-connected side,or cause loss of power
generation. Our company does not accept any responsibility for the re-
lated impacts and consequences caused by enabling the automatic con-
trol function of output voltage to connect to the grid.
9.3.2 Set language
The default language is English,touch twice in a row to enter the setting mode,a
single touch to switch the language, and touch twice to confirm the setting.
9.3.3 Set COM address
The default COM address is 1.Touch twice in a row to enter the setting mode, single
touch, the number +1,touch twice in a row to confirm the setting,lon g press for 5S
number to return to zero.
9.3.4 Set date and time
Touch twice to enter the parameter setting submenu, select the general set-
ting,touch twice to enter the general setting submenu, single touch to switch the
display interface, touch twice in the date and time interface to enter the setting
state,single touch,number + .