The corresponding relationship between the CAN communication port of the bidirectional DC-DC
box and the CAN communication port of lithium ion battery is show in the following table:
NO.
Bidirectional DC-DC
box
Battery pack
NO.
Bidirectional DC-DC
box
Battery pack
Pin1
White orange
White orange
Pin5
White blue
White blue
Pin2
Orange
Orange
Pin6
Green
Green
Pin3
White green
White green
Pin7
White brown
White brown
Pin4
Blue
Blue
Pin8
Brown
Brown
CAUTION
The communication interface RS485 or CAN between the
bidirectional DC-DC box and the lithium ion battery pack is
not properly connected or the electrical disconnection will
cause the equipment to work abnormally,or even damage the
equipment!
6.6 Connecting signal cable
This series inverter has two 8 Pin signal connectors,one is COM PORT connector,another is
SYS COM PORT connector. Signal Cable Ports as follows:
Procedure
Step 1 Insert the stripped and bared cable through pressure screw, seal ring, threaded sleeve in
sequence, insert cables into connection terminal according to number indicates on it and tighten
the screws firmly. Please try to pull out the wire to make sure the its well connected.
Step 2 Push the threaded sleeve into the socket, Tighten up the cap on the terminal.