12.2 Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension
belts. If it is no longer available, you can also use an equivalent carton. The box must
be capable of being closed completely and made to support both the weight and the
size of the inverter.
12.3 Storing the Inverter
Store the inverter in a dry place where ambient temperatures are always between
-25°C and +60°C.
12.4 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic waste
which apply at the installation site at that time. Ensure that the old unit and,
where applicable, any accessories are disposed of in a proper manner.
13 Technical Data
13.1 Specification
Model
Specifications
2500TL-XH
3000TL-XH
3600TL-XH
4200TL-XH
PV input quantities
Max. recommended PV
power(for module STC)
3500W
4200W
5040W
5880W
Vmax PV
500V
550V
Start voltage
100V
Nominal voltage
360V
PV input operating voltage
range
80-500V
80-550V

Table of Contents