Restart inverter, if problem still exist,
Contact Growatt.
If the ambient temperature of inverter is
lower than 60°C , restart inverter, if error
message still exists, contact Growatt.
Restart inverter, if problem still exist,
Contact Growatt.
DSP communicates with M3
abnormal
Restart inverter, if problem still exist,
update the DSP&M3 firmware;
Change DSP board or M3 board, if problem
still exist, contact Growatt.
Restart inverter, if problem still exist,
Contact Growatt.
The data sampled by the DSP and
redundant M3 is not the same.
Restart inverter, if problem still exist,
Contact Growatt.
Restart inverter, if problem still exist,
change power board, or contact Growatt.
11 Manufacturer Warranty
Please refer to the warranty card.
12 Decommissioning
12.1 Dismantling the Inverter
1 Disconnect the inverter as described in section.
2 Remove all connection cables from the inverter.
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled down.
3 Screw off all projecting cable glands.
4 Lift the inverter off the bracket and unscrew the bracket screws.