57
AC overvoltage category
Category III
AC input quantities
Nominal AC input voltage
230V
AC input voltage range
160-276V
AC input current(maximum
continuous)
11.3A
13.6A
16A
19A
Inrush current
<10A
Nominal frequency
50Hz/60Hz
AC input frequency range
45-55Hz/55-65Hz
Efficiency
Max. efficiency
98.2%
98.2%
98.2%
98.4%
Euro-eta
97.1%
97.1%
97.2%
97.2%
Protection devices
DC reverse-polarity protection
Integrated
DC switch
Integrated
DC Surge protection class
Type II
Insulation resistance
monitoring
Integrated
AC surge protection class
Type III
AC short-circuit protection
Integrated
Ground fault monitoring
Integrated
Grid monitoring
Integrated
Anti-islanding protection
Integrated
Residual-current monitoring
unit
Integrated
General data
Dimensions (W / H / D) in mm
375*350*160
Weight
10.8 kg
Operating temperature range
25 °C ... +60 °C
Noise emission (typical)
25 dB(A)
Altitude
2000m
Internal consumption at night
<10W
Topology
transformerless
Cooling
Natural convection
Ingress protection
IP65
Pollution degree outside the
enclosure
3
Pollution degree inside the
enclosure
2
Relative humidity
0~100%
DC connection
Helios H4-R/VP-D4/MC4