Debugging 7
1. Close the DC switch on the inverter. As long as the input DC voltage is greater than
MOV,the inverter display will show the following information: No mains connection error,the in-
verter LED will turn red.
If other information is displayed, please refer to Chapter 13.If you encounter any problems dur-
ing the debugging process and cannot solve it,please contact customer service.
2. Close the circuit breaker or switch between the inverter and the grid, the inverter will start a
countdown to the self-check,and after the self-check is normal,it will be connected to the grid.
3.In normal operation,the leaves of the inverter indicator window will turn green.
4. Finish debugging.
30

Other manuals for Growatt MOD 11KTL3-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MOD 11KTL3-X and is the answer not in the manual?

Growatt MOD 11KTL3-X Specifications

General IconGeneral
Product type-
Maximum power11000 W
Output current18.3 A
Output frequency50/60 Hz
MPP voltage range140 - 1000 V
Number of strings per MPPT1
Output power capacity (max)11 kVA
Input operation voltage (max)1100 V
Input operation voltage (min)160 V
Maximum input current per MPPT13 A
Output operation voltage (max)440 V
Output operation voltage (min)340 V
Total Harmonic Distortion (THD)3 %
Number of maximum power point tracking (MPPT)2
Operating temperature (T-T)-25 - 60 °C
Built-in displayYes
Display technologyOLED
Product colorWhite
Overvoltage categoryCAT II
Power protection featuresOver voltage, Short circuit
International Protection (IP) codeIP66
Weight and Dimensions IconWeight and Dimensions
Depth178 mm
Width425 mm
Height387 mm