Tips and disclaimers
When the inverter leaves the factory, the grid-connected voltage and frequency are set in ac-
cordance with the latest domestic standard;
If the grid voltage is lower or higher than the domestic legal requirements, the inverter cannot
be connected to the grid. After obtaining the permission of the local power operator, the user
can choose other voltage levels according to the voltage situation of the grid connection
point.
Excessive grid voltage may affect the normal use and service life of home appli-
ances on the grid-connected side,or cause loss of power generation. Our company
does not accept any responsibility for the related impacts and consequences
caused by enabling the automatic control function of output voltage to connect
to the grid.
9.3.3 Set language
The default language is English,touch twice in a row to enter the setting mode,a single touch
to switch the language, and touch twice to confirm the setting.
Fig 9.4
9.3.4 Set COM address
The default COM address is 1.Touch twice in a row to enter the setting mode, single touch, the
number +1,touch twice in a row to confirm the setting,long press for 5S number to return to
zero.
Fig 9.5
9.3.5 Set date and time
Touch twice to enter the parameter setting submenu, select the general setting,touch twice to
enter the general setting submenu, single touch to switch the display interface, touch twice in
the date and time interface to enter the setting state,single touch,number +.
34

Other manuals for Growatt MOD 11KTL3-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MOD 11KTL3-X and is the answer not in the manual?

Growatt MOD 11KTL3-X Specifications

General IconGeneral
Product type-
Maximum power11000 W
Output current18.3 A
Output frequency50/60 Hz
MPP voltage range140 - 1000 V
Number of strings per MPPT1
Output power capacity (max)11 kVA
Input operation voltage (max)1100 V
Input operation voltage (min)160 V
Maximum input current per MPPT13 A
Output operation voltage (max)440 V
Output operation voltage (min)340 V
Total Harmonic Distortion (THD)3 %
Number of maximum power point tracking (MPPT)2
Operating temperature (T-T)-25 - 60 °C
Built-in displayYes
Display technologyOLED
Product colorWhite
Overvoltage categoryCAT II
Power protection featuresOver voltage, Short circuit
International Protection (IP) codeIP66
Weight and Dimensions IconWeight and Dimensions
Depth178 mm
Width425 mm
Height387 mm