18
Notice: The set value of the parameter cannot be modified on the running state.if inverter is in auto mode
but you need to set value of the parameter. First setting P00.01=0manual operation mode settings press
for 2s, then inverter stops control. then you can set the P00~P15 group of function parameter.
Warning: Do not change parameters at random, otherwise the system might not work normally.
Function Parameters
SN
Name
Scope
Introduction
Default
Value
P00.01
Run commamd
model
0~2
0: manual operation
NOTE:When set P00 and P02 paramaters,first must
set manual operation power off the inverter, P15
not need.
1: auto operation mode
2: communication operation mode
1
P00.03
MAX. Output
frequency
P00.04~400.00Hz
The paramater is used to set the maximum output
frequency of theinverter
50.00Hz
Click enter to
set OK to return
Click to enter
Power off
Long press for
3seconds to shut down
Work mode
P00
Work mode
P00.18
Enter the main parameter
modification interface for log
press 2s for Enter key
Flip up toP00.18
Reset
Press Enter
Work mode
Set OK
Notice:After the factory settings are restored,all group
parameters will return to the default settings except for group
P02.