Upper limit of the
running frequency
The paramater is the upper limit of the output
frequency of the inverter which is lower than or
equal the maximum frequency
Lower limit of the
running frequency
If the solar energy is not sufficient to power the
motor,inverter will drop frequency runing. The
inverter will stop run when the runing frequency
lower than the lower limit frequency
0:The inverter runs in the forward diretion
1:The inverter runs in the reverse diretion
2:Forbid to run in reverse diretion
Function restore
parameter
0:No operation
1:Restore the default value
0:Decelerate to stop
1:Coast to stop
Rated power of
asynchronous
motor
Set this parameter according to rated power on
the pump nameplate
NOTE: when resetting the rated power of the
motor(P02.01),you can initialize the motor
parameter of (P02.02~P02.05)
Rated frequency
of asynchronous
motor
Set this parameter according to rated frequency on
the pump nameplate
Rated voltage of
asynchronous
motor
Set this parameter according to rated voltage on
the pump nameplate
Rated current of
asynchronous
motor
Set this parameter according to rated current on
the pump nameplate
Motor overload
protection factor
The pump motor over-load protection factor when
over-load, please refer to the rated current of
motor to set this parameter.
0:means the function is invalid
1:means the MPPT function is enabled
PID Max. Output
Frequency
P15.05~100.0%(100%correspongs P00.03)
P15.04 is used to limit the Max. value of target
frequency
PID Min. Output
Frequency
0.0%~ P15.04(100%correspongs P00.03)
P15.04 is used to limit the Min. value of target
frequency
Delay Time settiing of dry-water, under auto dry
run mode or water sensor mode