Grundfos DMH 25 Series - Page 33

Grundfos DMH 25 Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
13.7.5 Filling with gear oil
1. Check that the locking screw (B) is tightened.
2. Slacken and remove the oil-filling screw (F).
3. Set the stroke-length adjustment knob (L) to "0".
4. Slowly add the hydraulic oil through the oil-filling opening (F)
until the oil reaches the mark on the oil dipstick.
5. Wait 30 minutes.
6. Let the pump run for approx. 5 minutes with a stroke-length
setting of 0 %.
7. Let the pump run for approx. 10 minutes with a stroke-length
setting of 40 %.
13.7.6 Checking the oil level
1. Switch off the pump, check the oil level and add oil,
if necessary.
2. Refit the oil-filling screw (F).
Torques
13.7.7 Cleaning the ball non-return valve
Fig. 42
Contact pressure gauge
Removing the ball non-return valve and contact pressure
gauge
1. For pumps and pressure gauges in explosion-proof version,
unscrew the earth cable (4u).
2. Hold the connection piece (U) with a screwdriver and unscrew
the union nut (5u).
3. Unscrew the ball non-return valve (T) from the dosing head.
Cleaning the ball non-return valve
Fig. 43
Ball non-return valve
1. Unscrew the screw part (t6) using round pliers.
2. Clean all parts. Replace faulty parts by new ones.
3. Re-assemble the ball non-return valve.
4. Refit the ball non-return valve (T).
5. Screw the contact pressure gauge (S) and connection piece
(U) back on.
6. For pumps and pressure gauges in explosion-proof version,
screw the earth cable (4u) back on.
Caution
Risk of leaking oil and damage caused by oil
loss!
For each oil change, a new flat gasket (1b) must
be fitted!
Caution
After initial start-up and after each time the
diaphragm is changed, tighten the dosing head
screws.
After approximately 6-10 operating hours or
two days, cross-tighten the dosing head screws
using a torque wrench.
Pump type
Torque
[Nm]
DMH 251, 10 bar 8-10
DMH 251, 16 bar 10-12
DMH 251, 25 bar 13-15
DMH 252 8-10
DMH 253 10-12
DMH 254 50-54
DMH 255 50-54
DMH 257 50-54
Note
Only clean the ball non-return valve after
a diaphragm breakage!
TM03 6453 4506
T
5u
4u
3u
2)
U
5s
3u
2u
S
6s
Pos. Components
S Contact pressure gauge
5s Union nut
6s Contact output
T Ball non-return valve
U Connection piece
2u Deaeration screw
3u O-rings
4u Connection for earth cable
5u Union nut
* 2) or locking unit (instead of contact pressure gauge
and its connection)
TM03 6476 4506
Pos. Components
t1 O-ring
t2 Ball non-return valve body
t3 Ball
t4 Spring sheath
t5 Pressure spring
t6 Screw part
t7 O-ring
Caution
Tighten the ball non-return valve and connection
piece by hand only.
t7
t6
t5
t4
t3
t1
t2
t1