11
Functions
DME and DMS
Indicator lights and alarm output (60 to 940)
Condition Green LED Red LED Display
Alarm
output1
Pump running On Off
Normal
indication
Set to stop Flashing Off
Normal
indication
Pump fault Off On EEPROM
Supply failure Off Off Off
Pump running, low
chemical level
2
On On LOW
Empty tank
2
Off On EMPTY
Analog signal < 2 mA Off On NO mA
The dosed quantity is
too small according to
the signal from the
dosing monitor
3
On On
NO
FLOW
Overheating Off On
MAX
TEMP
Internal
communication failure
Off On
INT
COM
Internal Hall Failure
4
Off On HALL
Diaphragm failure
(leakage)
5
Off On LEAKAGE
Max. pressure
exceeded
5
Off
6
On
OVER-
LOAD
More pulses than
capacity
On On
MAX
FLOW
No detection of
motor rotation
4
On On ORIGO
132
NC NO C
132
NC NO C
1
23
NC NO C
132
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
23
NC NO C
1
Control variant AR, only.
2
Requires connection to level sensors.
3
Requires activation of the dosing monitoring function and connection
to a dosing monitor.
4
Please contact a Grundfos service centre.
5
Alarms can be reset after fault conditions are back to normal.
6
The pump will make 10 attempts to restart before going into
permanent off mode.
Condition Green LED Red LED Display
Alarm
output1
Dm123.book Page 11 Tuesday, February 8, 2005 8:24 AM