51
Accessories
Flow indicator
Flow indicator
The flow indicator is used for discharge monitoring.
When the dosing pump is discharging liquid, the white
ball will jump in the transparent pipe. Each dosing
stroke causes a ball jump. The design of the flow indi-
cator allows ball movements to be seen at flow rates
from 0.026 to 11.9 GPH.
At a steady flow, the ball will always be in the top posi-
tion.
The flow indicator installs and retrofits easily.
Material: PVC grey, PVC transparent,
PVDF, FKM, ceramic AI
2
O
3
.
Maximum pressure: 145 psi (10 bar)
Maximum pulsed flow: 11.9 GPH (45 l/h).
Dimensions
TM01 9791 3100
TM01 9800 3200
Pump type
Dimensions
Product number
A B C [mm] D [mm]
DME 2 to 48
DMS
M30 x 3.5 M30 x 3.5 44 55 96446763
Dm123.book Page 51 Tuesday, February 8, 2005 8:24 AM