CALIBRATION ERRORS
MESSAGE DESCRIPTION
Code92
„Stpt
Setup
A parameter entry is required for a setpoint’s Activation Limit,
Deactivation Limit, or Compare parameter. Pressing any key will
automatically select the offending parameter and allow you to correct it.
CoDE95
SyErr
NvRam
The EEPROM size is too small to allocate the database requested.
CoDE95
SyErr
HSR00
An error occurred at startup or during operation. Contact GSE.
CoDE95
SyErr
Typ04
An error occurred at startup. Contact GSE.
Code96
Erase
Boot!
An attempt was made to enter an instrument serial number or board
serial number with the flash already programmed.
CoDE99
Can't
Set!
An attempt to enter a value for a parameter which is not field changeable,
such as the serial numbers or the audit trail counter results in this
message.
P___
Invld
Mode!
An attempt was made to access a non-existent parameter. Key in a valid
parameter and press
>, or press only > or to proceed to the
nearest lower valid parameter.
Mode
<100!
An attempt was made to access a weigh mode parameter from within the
setup mode. Valid setup mode parameters contain three or more digits.
Press
Enter
The > key was pressed at a “pick instance” prompt. You must press
to select an instance, or K to abort the instance entry.
Okay?
#####
This is not an error. Press to acknowledge your entry, or K to re-
enter.
Cksum
error
Upon each power-up, the Model 672 tests the integrity of its firmware. If
the result is not correct this message is displayed and the scale is not
usable. ReFlash the Model 672.
MdBus
Max!
An attempt was made to modify the modbus parameter map past its limit
of P6999.
COMMUNICATION ERRORS
MESSAGE DESCRIPTION
prtyX
error
The parity of a received character did not match the parity specified in the
setup mode at P202. This could also result if the baud rate (P200) or the
number of data bits (P201) are incorrect. The ‘X’ in the error message
represents the COMM port number on which the problem occurred.
ovrnX
error
An overrun error occurred where additional characters were received
while the receive buffer was full. The additional characters will be lost.
The ‘X’ in the error message represents the COMM port number on which
the problem occurred.
frmgX
error
The stop bit of a received character did not occur when it was expected.
This could be the result of an incorrect baud rate (P200), incorrect number
of data bits (P201), or incorrect parity setting (P202). The ‘X’ in the error
message represents the COMM port number on which the problem
occurred.