56
Parameter
<voltage>
<NRf> 0% ~ 105% of the rated output
voltage.
<current>
<NRf> 0% ~ 105% of the rated output
current.
MIN
0 volts/0 amps
MAX
Maxium value for the present range.
Return parameter
<NRf>
Returns the voltage and current.
Example
APPL 5.05,1.1
Sets the voltage and current to 5.05V and 1.1A.
Query Example
APPL?
+5.050, +1.100
Returns voltage (5.05V) and current (1.1A) setting.
Display Commands
DISPlay:MENU[:NAME] .................................................... 56
DISPlay[:WINDow]:TEXT:CLEar ..................................... 57
DISPlay[:WINDow]:TEXT[:DATA] .................................. 57
DISPlay:BLINk ...................................................................... 57
DISPlay:MENU[:NAME]
Set
Query
Description
The DISPlay MENU command selects a screen
menu or queries the current screen menu.
Syntax
Query Sytax
DISPlay:MENU[:NAME] <NR1>
DISPlay:MENU[:NAME]?
Parameter/
Return parameter
<NR1>
Description
0
Measurement-Voltage / Measurement-
Current
1
Measurement-Voltage / Measurement-Power
2
Measurement-Power / Measurement-Current
3
Set Menu
4
OVP / OCP Menu
5~99
Not Used.
100~199
F-00~99 Menu.