REMOTE CONTROL 
73 
[SOURce:]VOLTage[:LEVel]:TRIGgered
[:AMPLitude] 
 
Sets or queries the voltage level in volts when a 
software trigger has been generated.  
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] 
{<NRf>|MIN|MAX} 
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? 
[MIN|MAX] 
0%~105% of the rated voltage output in volts. 
SOUR:VOLT:LEV:TRIG:AMPL 10 
Sets the voltage level to 10 volts when a software 
trigger is generated. 
[SOURce:]VOLTage:PROTection[:LEVel] 
 
Sets or queries the overvoltage protection level. 
[SOURce:]VOLTage:PROTection[:LEVel] 
{<NRf>|MIN|MAX}  
[SOURce:]VOLTage:PROTection[:LEVel]? [MIN|MAX] 
SOUR:VOLT:PROT:LEV MAX 
Sets the OVP level to its maximum. 
[SOURce:]VOLTage:SLEW:RISing 
 
Sets or queries the rising voltage slew rate. This is 
only applicable for CV slew rate priority mode.