REMOTE CONTROL 
75 
Trigger Commands 
The trigger commands generate and configure software triggers.   
 
TRIGger:TRANsient[:IMMediate] ...................................... 75 
TRIGger:TRANsient:SOURce ............................................ 75 
TRIGger:OUTPut[:IMMediate] .......................................... 76 
TRIGger:OUTPut:SOURce ................................................. 76 
Trigger Command Examples ............................................... 76 
 
TRIGger:TRANsient[:IMMediate] 
 
Generates a software trigger for the transient 
trigger system. On a trigger, sets the voltage & 
current. Refer to the :CURR:TRIG and VOLT:TRIG 
commands on page 69 and 73, respectively. 
TRIGger:TRANsient[:IMMediate] 
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] 
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] 
 
Sets or queries the trigger source for the transient 
system. 
TRIGger:TRANsient:SOURce {BUS | IMMediate} 
TRIGger:TRANsient:SOURce? 
Internal software trigger. Waits for the 
*TRG (or IEEE 488.1 “get” group 
execute trigger) command to start the 
trigger. 
Starts the trigger immediately. 
(default) 
TRIG:TRAN:SOUR BUS 
Sets the trigger source as BUS.