PSW Series User Manual 
36 
MEASure[:SCALar]:VOLTage[:DC] 
Query
 
Description 
Takes a measurement and returns the average 
output voltage. 
Syntax MEASure[:SCALar]:VOLTage[:DC]? 
Return  <NRf> 
Returns the voltage in volts. 
MEASure[:SCALar]:POWer[:DC] 
Query
 
Description 
Takes a measurement and returns the average 
output power. 
Syntax MEASure[:SCALar]:POWer[:DC]? 
Return  <NRf> 
Returns the power measured in watts. 
Output Commands 
 
 
OUTPut:DELay:ON ............................................................36
OUTPut:DELay:OFF ........................................................... 37
OUTPut:MODE ................................................................... 37
OUTPut[:STATe][:IMMediate] ........................................... 37
OUTPut[:STATe]:TRIGgered ............................................. 38
OUTPut:PROTection:CLEar .............................................. 38
OUTPut:PROTection:TRIPped .......................................... 38
 
OUTPut:DELay:ON 
Set
Query
 
Description 
Sets the Delay Time in seconds for turning the 
output on. The delay is set to 0.000 by default. 
Syntax 
Query Syntax 
OUTPut:DELay:ON <NRf> 
OUTPut:DELay:ON? 
Parameter  <NRf> 
0.00~99.99 seconds, where 0=no delay.  
Return parameter  <NRf> 
Returns the delay on time in seconds until the 
output is turned on.