Chapter 3 Troubleshooting
3-2
II.
z The console cable is in good condition and the terminal
(HyperTerminal for example) parameter settings are
correct. Refer to section
2.4.1 Configuring Terminal
Parameters
” for information about terminal parameter
settings.
Garbled characters on the terminal
Make sure you have set on your terminal the following
parameters correctly (HyperTerminal):
z Bits per second = 9600
z Data bits = 8
z Parity = None
z Stop bits = 1
z Flow control = None
z Terminal emulation = VT100 or Auto detect
Reconfigure the parameters if their values are different from the
above.