Operating power module failure
Symptom
An operating power module fails.
Troubleshooting flowchart
Figure 2 Troubleshooting operating power module failure
Solution
To resolve the problem:
1. Identify the operating state of the power module.
[Sysname]display power
Slot 2:
PowerID State Mode Current(A) Voltage(V) Power(W)
1 Normal -- -- -- --
2 Absent -- -- -- --
If the power module is in Absent state, go to step 2. If the power module is in Fault state, go to
step 3.
2. R
emove and reinstall the power module to make sure the power module is installed securely. Then,
execute the display power command to verify that the power module has changed to Normal state.
If the power module remains in Absent state, replace the power module.
3. When the power module is in Fault state, perform the following tasks: