18
Troubleshooting flowchart
Figure 9 Troubleshooting IRF fabric establishment failure
Solution
To resolve the problem:
1. Verify that the number of member devices does not exceed 9.
If you are adding a new member device to an existing IRF fabric or merging IRF fabrics, use the
display irf command to identify the number of member devices in the IRF fabrics. If the total number
of member devices exceeds the upper limit, the IRF setup will fail.
No
Yes
No
Yes
No
Yes
IRF setup
failure
No
No
Yes
Yes
No
Yes
Resolved?
No
Yes
Yes
No
Yes
No
Yes
You cannot add the device to
the IRF fabric or complete IRF
merge
Yes
No
Member ID unique?
Modify IRF port bindings or
reconnect physical interfaces
Number of members
fewer than the upper limit?
IRF port bindings
or physical IRF connections
correct?
No
Resolved?
10 Gbps or 40 Gbps IRF links used?
Replace with 10 Gbps or 40
Gbps transceiver modules or
DAC cables
Resolved?
(Optional.)
Transceiver modules at link ends are
the same type?
Resolved?
IRF links up? Resolved?
Assign a unique member ID to
each member device
Bring up the IRF links/activate
IRF port configuration
Replace the transceiver
modules to be the same type
Same software version?
Upgrade software to the same
version in the fabric
Contact the support
No
Resolved?
End
Yes
No

Table of Contents

Other manuals for H3C S5560-EI series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5560-EI series and is the answer not in the manual?

H3C S5560-EI series Specifications

General IconGeneral
BrandH3C
ModelS5560-EI series
CategorySwitch
LanguageEnglish

Related product manuals