40
system. Before setting this mode, you must delete all RAID arrays and
hot spare drives, and perform the Uninitializing drives operation for all
drives.
Auto Volume
In this mode, raw physical drives with system partitions are exposed to
the system, and physical drives without system partitions are
configured as simple volumes. Before setting this mode, you must
delete all RAID arrays and hot spare drives in the system.
Simple Volume
In this mode, only non-redundant RAID arrays with the simple volume
level (each contains only one drive) can be created. RAID arrays with
other RAID levels cannot be created. Before setting this mode, you
must delete all RAID arrays and hot spare drives in the system.
5. Reboot the operating system to make the storage controller operating mode configuration take
effect.
Scanning drives
The storage controller might fail to timely recognize drives after the drives are hot swapped. To
solve this problem, you can scan drives.
To scan drives:
1. On the PMC RAID management screen as shown in Figure 67, select Logical Device
Configuration, and press Enter.
Figure 67 PMC RAID management screen
2. On the screen as shown in Figure 68, select Rescan Drives, and press Enter.