Protection Functions
1. Over-Temperature Protection
To avoid overheating and deteriorating the ash
head, do not re more than 30 continuous ashes in
fast succession at 1/1 full power. After 30 continuous
ashes, allow a rest time of at least 10 minutes
If you re more than 30 continuous ashes and then
re more ashes in short intervals, the inner over-
temperature protection function may be activated and
make the recycling time over 10 seconds. If this occurs,
allow a rest time of about 10 minutes, and the ash unit
will then return to normal
When the over-temperature protection is active,
<
> is shown on the LCD display
Power Output level
Number
of Flashes
1/1
1/2 +0.7
1/2 +0.3
1/2
1/4(+0.3,+07)
1/8(+0.3,+07)
1/16(+0.3,+07)
1/32(+0.3,+07)
1/64(+0.3,+07)
1/128(+0.3,+07)
30
40
50
60
100
200
300
500
1000
Numberofashesthat
will activate over-
temperature
protection in high-speed
sync triggering mode:
Power Output Times
1/1
1/2(+0.3,+07)
1/4(+0.3,+07)
1/8(+0.3,+07)
1/16(+0.3,+07)
1/32(+0.3,+07)
1/64(+0.3,+07)
1/128(+0.3,+07)
15
20
30
40
50
Number of
ashesthat
will activate
over-
temperature
protection: