OPERATION
-17-
Alarm Indicator (13)
Illuminates when the power supply has exceeded duty-cycle and entered an
over-temperature condition. The unit will automatically reset once cooled and lamp will go
off.
JOB program save (16)
In the JOB mode, 100 different JOB records can be stored and recalled. When leaving
the factory, has no saved JOB programs; therefore, operator must first save a program.
Saving the JOB program
⚫ Set JOB mode parameters (welding function, welding mode, welding parameters,
etc).
⚫ Press the JOB button (16) and LED will illuminate.
⚫ Select JOB number by the adjustment Knob (15) shown on the digital meter (8).
⚫ Press the Save/Delete button (17) to save the JOB under the selected number.
Recall the JOB program
⚫ Press the JOB button (16) and the JOB LED will illuminate.
⚫ Selectthe required JOB number by the adjustment Knob (15) as shown on the meter
(8).
⚫ Press the JOB button (16) again and the JOB LED is off that signals exit of JOB
mode.
Function button (18)
• Implicit parameter menu and parameter adjustment method for import and
export
a) Press the function button (18) indicator light “ON” indicates in parameter adjusting
mode.
b) Scroll through parameter codes turning knob (14). Codes are shown on meter (3).
Once parameter is selected, adjust the knob (15) with selection shown on the meter
(8).
c) Press the function button(18)again, light “OFF” signals exit parameter adjusting
mode.