EasyManua.ls Logo

H&S HSM250 - Operation Environment; Operation Notices

H&S HSM250
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
-63-
3.0
1.2
100-12
0
19-21
40-60
13-17
15-20
4.0
1.2
120-15
0
20-22
50-70
15-20
15-20
6.0
1.2
150-18
0
20-23
50-70
18-22
18-22
4.0
1.2
180-21
0
21-24
35-50
18-22
16-18
4.0
1.6
180-21
0
18-20
35-45
18-22
18-22
6.0
1.2
220-25
0
24-25
50-60
18-22
16-24
6.0
1.6
220-24
0
20-24
37-50
18-22
16-24
8.0
1.6
250-30
0
25-26
60-65
18-22
16-24
12.0
1.6
300-40
0
26-28
65-75
18-22
16-24
§4.6 Operation Environment
▲ Height above sea level ≤1000 M
▲ Operation temperature range 14 - 104°F (-10~+40°C)
▲ Air relative humidity is below 90%
▲ Preferable site the machine some angles above the floor level does not exceed 15°.
▲ Protect the machine against high moisture, water AND against direct sunshine.
▲ Take care that there is sufficient ventilation during welding. There must be at least
1-1/2” (38cm) free distance between the machine and wall.
§4.7 Operation Notices
▲ Read Section §1 carefully before starting to use this equipment.
▲ Ensure that the input is 208-240VAC, single-phase: 50/60Hz.
▲ Before operation, clear the working area. Do not watch the arc in unprotected eyes.
▲ Ensure good ventilation of the machine to improve duty cycle and life.
▲ Turn off power supply when the operation finished for energy consumption efficiency.
▲ When power switch shuts off protectively because of failure. Don’t restart it until
problem has been resolved. Otherwise, permanent damage could occur.
▲ In case of problems, contact your local dealer.