§4.6 Operation Environment
▲ Height above sea level ≤1000 M
▲ Operation temperature range 14 - 104°F (-10~+40°C)
▲ Air relative humidity is below 90%
▲ Preferable site the machine some angles above the floor level does not exceed 15°.
▲ Protect the machine against high moisture, water AND against direct sunshine.
▲ Take care that there is sufficient ventilation during welding. There must be at least
1-1/2” (38cm) free distance between the machine and wall.
§4.7 Operation Notices
▲ Read Section §1 carefully before starting to use this equipment.
▲ Ensure that the input is 208-240VAC, single-phase: 50/60Hz.
▲ Before operation, clear the working area. Do not watch the arc in unprotected eyes.
▲ Ensure good ventilation of the machine to improve duty cycle and life.
▲ Turn off power supply when the operation finished for energy consumption efficiency.
▲ When power switch shuts off protectively because of failure. Don’t restart it until
problem has been resolved. Otherwise, permanent damage could occur.
▲ In case of problems, contact your local dealer.