§7.3 List of Error Codes
Error Type
Error
code
Description
Lamp status
Thermal relay
E01
Over-heating (1st thermal relay)
Yellow lamp(thermal
protection) always on
E02
Over-heating (2nd thermal relay)
Yellow lamp(thermal
protection) always on
E03
Over-heating (3rd thermal relay)
Yellow lamp(thermal
protection) always on
E04
Over-heating (4th thermal relay)
Yellow lamp(thermal
protection) always on
E09
Over-heating (Program default)
Yellow lamp(thermal
protection) always on
Welding
machine
E10
Phase loss
Yellow lamp(thermal
protection) always on
E11
N/A
Yellow lamp(lack
water) always on
E12
No gas
Red lamp always on
E13
Under voltage
Yellow lamp(thermal
protection) always on
E14
Over voltage
Yellow lamp(thermal
protection) always on
E15
Over current
Yellow lamp(thermal
protection) always on
E16
Wire feeder over load
Switch
E20
Button fault on operating panel
when switch on the machine
Yellow lamp(thermal
protection) always on
E21
Other faults on operating panel
when switch on the machine
Yellow lamp(thermal
protection) always on
E22
Torch fault when switch on the
machine
Yellow lamp(thermal
protection) always on
E23
Torch fault during normal
working process
Yellow lamp(thermal
protection) always on
Accessory
E30
Cutting torch disconnection
Red lamp blink
E31
N/A
Yellow lamp(lack
water) always on
Communication
E40
Connection problem between
wire feeder and power source
E41
Communication error