EasyManua.ls Logo

Harris Platinum Z2 CD - Default Chapter; Table of Contents

Default Icon
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
888-2406-002 1
WARNING: Disconnect primary power prior to servicing.
Table of Contents
1 Introduction/Specifications
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Harris DIGIT Digital FM Exciter . . . . . . . . . . . . . . .1-3
Harris SuperCiter Analog Exciter. . . . . . . . . . . . . . . 1-3
Redundant Exciters . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
PA/IPA Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
RF Combining. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Directional RF Sample Port . . . . . . . . . . . . . . . . . . . 1-5
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Air System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Performance Specifications. . . . . . . . . . . . . . . . . . . . . 1-5
2 Installation & Initial Turn-On
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Returns and Exchanges . . . . . . . . . . . . . . . . . . . . . . . .2-1
Air Cooling Requirements. . . . . . . . . . . . . . . . . . . . . . 2-2
Z2 Transmitter Installation . . . . . . . . . . . . . . . . . . . . . 2-2
Transmitter Placement . . . . . . . . . . . . . . . . . . . . . . . 2-3
Removal of Pallet Bolts . . . . . . . . . . . . . . . . . . . . . 2-3
Visual Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Exciter Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
3-Phase Power Supply Installation . . . . . . . . . . . . . .2-5
Power Transformer Tapping. . . . . . . . . . . . . . . . . . 2-5
Power Supply Connections . . . . . . . . . . . . . . . . . . 2-5
Dual Power Supply Option. . . . . . . . . . . . . . . . . . . 2-8
Single Phase Power Supply Installation . . . . . . . . . . 2-9
Power Transformer Tapping. . . . . . . . . . . . . . . . . . 2-9
Power Supply Connections . . . . . . . . . . . . . . . . . . 2-9
Dual Power Supply Option. . . . . . . . . . . . . . . . . . 2-12
Transmitter AC Connections. . . . . . . . . . . . . . . . . . 2-13
Information concerning some 360 to 416
volt systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Three Phase AC Connection . . . . . . . . . . . . . . . . 2-14
Single Phase AC Connection . . . . . . . . . . . . . . . . 2-15
Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-15
Low Voltage Power Supply and Blower . . . . . . .2-16
Exciter AC Voltage Selection. . . . . . . . . . . . . . . . 2-16
RF Output Connection . . . . . . . . . . . . . . . . . . . . . .2-16
Audio Input Connections . . . . . . . . . . . . . . . . . . . . 2-16
External and Failsafe Interlock Connections . . . . .2-17
External Interlock Connection . . . . . . . . . . . . . . . 2-17
Failsafe Interlock Connection . . . . . . . . . . . . . . . 2-17
Initial Turn-on. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Remote Control Connections . . . . . . . . . . . . . . . . . . 2-23
Remote/Extended Control and Status Connections 2-24
Typical remote/extended control and status connec-
tions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
Extended Metering. . . . . . . . . . . . . . . . . . . . . . . . 2-26
UPS IN/Remote Exciter Select,
Configurable Input TB1-9. . . . . . . . . . . . . . . . . . . 2-26
Using an Uninterruptable Power Supply or UPS . . . 2-27
Setting the UPS Power Level. . . . . . . . . . . . . . . . 2-27
Optimizing Efficiency. . . . . . . . . . . . . . . . . . . . . . . . 2-28
Setting the Low Power Alarm. . . . . . . . . . . . . . . . . . 2-29
Jumper Settings for Installation of a Harris Exciter . 2-29
Power Distribution for Optimum Transmitter
Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Overheating from Line Unbalance. . . . . . . . . . . . . 2-33
Transmitter Noise Performance . . . . . . . . . . . . . . . 2-33
The Causes of Line Unbalance. . . . . . . . . . . . . . . . 2-34
Three Phase Delta Distribution Transformers . . . . 2-34
Three Phase Wye Distribution Transformers . . . . . 2-35
3 Operator Guide
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Transmitter Controls . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Transmitter Metering. . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Forward Power (FWD PWR) Units of Measure . . . 3-3
Reflected Power (RFL PWR) Units of Measure . . . 3-3
Using the Diagnostic Display . . . . . . . . . . . . . . . . . . . 3-4
HOME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
BACK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
MORE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Diagnostic Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Asterisk and Pound Signs(*, #) . . . . . . . . . . . . . . . . 3-8
Fault Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Emergency Operating Procedures. . . . . . . . . . . . . . . 3-10
Multiple PA Failures in a Foursome. . . . . . . . . . . . 3-10
Manual Exciter Switching. . . . . . . . . . . . . . . . . . . . . 3-11
Manual IPA Switching . . . . . . . . . . . . . . . . . . . . . . . 3-11
Optimizing Efficiency. . . . . . . . . . . . . . . . . . . . . . . . 3-12
Fan Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
4 Overall System Theory
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

Table of Contents

Related product manuals