Loading...
2-8 888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
2.5.4.3 Dual Power Supply Option
To add redundancy the Z2 can be configured with an optional second power supply.
The installation procedure only changes slightly for this configuration. The
following lists only the additions to the above procedure.
h. Before rolling the power supply all of the way into the cabinet, connect the
blue ribbon cable labelled W12 to J4 on the power supply which will be clos-
est to the rear of the transmitter. The supply may now be rolled all of the way
into the cabinet.
i. The Wago block on the front of the power supply tray, A17TB1, has 8 con-
nections compared to the 6 connections for the single supply configuration.
The connections are shown in Figure 2-3 and are as follows:
1. Wire #1 connects to terminal #1
2. Wire #2 connects to terminal #3
3. Wire #3 connects to terminal #5
4. Wire #40 connects to terminal #7
5. Wire *#41 connects to terminal #8
(*Wire #41 is not used on 3 phase 4-wire system)
Figure 2-3 3-Phase Dual Power Supply Top View