6-30 888-2406-002
WARNING: Disconnect primary power prior to servicing.
Troubleshooting
Table 6-2 Power Supply Tap Troubleshooting Chart
3 Phase Power Supply Single Phase
Supply
Rectifier Board "A" Rectifier Board "B"
SCRs Fuses SCRs Fuses SCRs Fuses
TAP 1
48V
Q13 F13 Q4 F4 CR4 F4
Q17 F17 Q8 F8 CR8 F8
Q21 F21 Q12 F12
TAP 2
50V
Q14 F14 Q3 F3 CR3 F3
Q18 F18 Q7 F7 CR7 F7
Q22 F22 Q11 F11
TAP 3
52V
Q15 F15 Q2 F2 CR2 F2
Q19 F19 Q6 F6 CR6 F6
Q23 F23 Q10 F10
TAP 4
54V
Q16 F16 Q1 F1 CR1 F1
Q20 F20 Q5 F5 CR5 F5
Q24 F24 Q9 F9
Soft Start
Tap
There are no Soft Start SCRs
on Rectifier Board "A"
Q34 F4 Q10 F1
Q35 F8 Q11 F2
Q36 F12
All component numbers should be verified with the schematic.