2-6 888-2406-002
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
Figure 2-1 3-Phase Power Supply Top View
b. The cable labelled A1P2 (multi-conductor cable with gray connector) plugs
into its mating connector on the left wall of the power supply compartment,
see Figure 2-1.
c. Wires #1, #2, and #3 (orange cables tied up on the left side of the power sup-
ply compartment) and two smaller gray wires #40 and *#41 plug into the gray
Wago block connector, A17TB1 on the front of the power supply tray (A17
designates a component on the power supply tray). See Figure 2-1. The wago
block has 5 terminals labelled terminal #1 on the left and #5 on the right. The
connections are as follows:
1. Wire #1 connects to terminal #1
2. Wire #2 connects to terminal #2
3. Wire #3 connects to terminal #3
4. Wire #40 connects to terminal #4
5. Wire *#41 connects to terminal #5
(*Wire #41 is not used on 3 phase 4-wire system)