RF-5800H 150-WATT COMMUNICATION SYSTEM
TROUBLESHOOTING
TAP-2: NO POWER UP (BASE OR TRANSIT
CASE)
RF-5800H 150-Watt Base Station or Transit Case System does not
power up.
INITIAL CHECKS
•
Make sure all cables are connected.
• Make sure all units are properly seated.
• Make sure all connections are tight and there are no broken
connections.
PROCEDURE
Check AC line voltage being supplied to RF-5051PS.
YN
Is input voltage between 90 and 300 VAC?
Connect RF-5051PS to a proper AC source.
Check AC line voltage at the output of Primary AC Power Cable
(10181-9831) connected to J17 on the RF-5051PS.
YN
Is AC voltage present?
Remove and replace Primary AC Power Cable
(10181-9831).
YN
Does system power up?
Refer to troubleshooting index.
Return system to operational readiness.
Check DC output voltage from RF-5051PS at connector J15.
YN
Is output voltage +28.3 VDC nominal?
Remove and replace RF-5051PS.
YN
Does system power up?
Refer to troubleshooting index.
Return system to operational readiness.
Check RF-5051PS DC output voltage at the output of DC Power
Cable Assembly (10181-9833-004) connected to J10 on the
RF-5833H-PA.
YN
Is DC voltage present?
Remove and replace DC Power Cable Assembly
(10181-9833-004).
YN
Does system power up?
Refer to troubleshooting index.
Return system to operational readiness.
A
A
Check CB1 on RF-5833H-PA.
YN
Is CB1 closed?
Reset circuit breaker and retest system.
YN
Does CB1 stay closed?
Remove and replace RF-5833H-PA and
retest system.
YN
Does CB1 stay closed?
Reinstall previously removed
RF-5833H-PA. Remove and
replace RF-5800H-MP and
retest system.
YN
Does CB1 stay closed?
Refer to
troubleshooting index
to identify faulty
system cable.
Return system to operational
readiness.
Return system to operational readiness.
YN
Does system power up?
Remove and replace RF-5800H-MP.
Return system to operational readiness.
Return system to operational readiness.
Remove and replace RF-5833H-PA.
YN
Does system power up?
Remove and replace RF-5800H-MP. Return system to
operational readiness.
Return system to operational readiness.