29
WX232
Figure 8. Reset button of the overheat protector
Abbildung 8. Rückstellknopf des Überhitzungsschutzes
4. SPARE PARTS 4. ERSATZTEILE
1 Control panel (CS170) Bedienfeld (CS170) WX601
2 Installation ange Montagemanschette ZVR-653
3 Temperature sensor Temperaturfühler WX232
4 Temperature sensor (optional) Temperaturfühler (wahlweise) WX325
5 Data cable 5 m Datakabel 5 m WX311
6 Data cable extension 10 m (optional) Verlängerungskabel 10 m (wahlweise) WX313
7
Circuit board (XT2001) Platine (XT2001)
WX351
3.4. Resetting the Overheat Protector
The sensor box (WX232) contains a temperature
sensor and an overheat protector. If the
temperature in the sensors environment rises too
high, the overheat protector cuts off the heater
power. Resetting the overheat protector is shown
in gure 8.
Note! The reason for the going off must be deter-
mined before the button is pressed.
3.4. Zurückstellen der Überhitzungsschutzes
Das Fühlergehäuse (WX232) enthält einen Tempe-
raturfühler und einen Überhitzungsschutz. Wenn
die Temperatur in der Umgebung des Temperatur-
fühlers zu stark ansteigt, unterbricht der Überhit-
zungsschutz die Stromzufuhr. Das Zurücksetzen
des Überhitzungsschutzes wird in Abbildung 8
dargstellt.
Achtung! Bevor Sie den Knopf drücken, müssen
Sie die Ursache für die Auslösung des Überhit-
zungsschutzes ermitteln.
54 631 2 7